| Sign In | Join Free | My ecer.co.uk |
|
Brand Name : KACISE
Model Number : KLD802
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Certification : CE
Medium : non-corrosive liquid, slightly corrosive liquid
Measuring range : 0.1m~10/20/30/60/100m
Process connection : flange ≥ DN80
Process temperature : -40~110℃
Process pressure : -0.1~1.6MPa
Antenna size : 32mm lens antenna
Antenna material : PTFE
Accuracy : ±1mm (range below 35m)、±5mm (range between 35m and 100m)
Protection class : IP67
Center frequency : 80GHz
Launch angle : 3°
Power supply : DC24V/DC12~24V /AC220V
Casing : aluminum / plastic / stainless steel
Signal output : 4...20mA/HART protocol/RS485 Modbus
KLD800 series 80G radar level gauge adopts frequency modulated continuous wave (FMCW) technology. The antenna emits a high-frequency FM radar signal, and the frequency of the radar signal increases linearly. The transmitted radar signal is received by the same antenna after being reflected by the measured medium. At the same time, the frequency difference between the transmitted signal frequency and the received signal frequency is proportional to the measured distance. The collected frequency difference signal is subjected to fast Fourier transform (FFT) to obtain the spectrum of the reflected echo, and the distance to the target to be measured is calculated based on this.
KLD802 | Medium: non-corrosive liquid, slightly corrosive liquid |
1.Flange Installation
When using flange installation, the minimum distance between the instrument and the tank wall should be 200mm.


2.Hoisting Installation

When installing the instrument, avoid installing it above the material inlet, and try to avoid various objects that affect the signal, such as stirring paddles, etc.


Under extremely complex working conditions, the instrument can work normally if there is no obstacle in the area with a radius of 20cm centered on the installation point.
Installation connection diagram:
The maximum installation spool height H max depends on the installation spool diameter D and the size of the product launch angle.
Too long installation connection will affect the radar performance.
Casing Dimension
Unit in mm:

Xi'an Kacise Optronics Tech Co., Ltd considers itself a solution provider and manufacturer. We offer maximum flexibility and a cost-optimised offer for our OEM customers.
What we could provide:
The range includes customized shell version/color, thread type(G-Thread/NPT Thread), Customized Software, prints, manual and catalog. If you are interested in installing at your side, Radar Module is available for sure.
|
|
IP67 80GHz Radar Level Gauge with 32mm Lens Antenna for Slightly Corrosive Liquid KLD802 Images |