Brand Name : KACISE
Model Number : KLD802
Certification : CE,ISO9001
Place of Origin : CHINA
MOQ : 1pcs
Price : 200-700
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram, Paypal
Supply Ability : 10000pcs/month
Delivery Time : 5-7 working days
Packaging Details : carton box
Frequency : 80GHz
Output : two-wire /4...20mA/HART protocol
Explosion-proof : Exia IIC T6 Ga/Exd ia IIC T6 Gb
Protection : IP67
Range : 0.1m~100m
Medium : non-corrosive liquid, slightly corrosive liquid
Process pressure : -0.1~1.6MPa
Power supply : two-wire /DC24V four-wire /DC12~24V four-wire /AC220V
The KLD802 80G radar level gauge employs frequency modulated continuous wave (FMCW) technology. The antenna transmits high-frequency FM radar signals with linearly increasing frequency. These signals are reflected by the measured medium and received by the same antenna. The frequency difference between transmitted and received signals is proportional to the measured distance. Through fast Fourier transform (FFT) processing of the frequency difference signal, the echo spectrum is obtained, enabling precise distance calculation to the target.
The radar antenna transmits narrow microwave pulses that reflect off the measured medium surface and return to the antenna system. These signals are processed by electronic circuits and converted into level signals. Due to the extremely fast transmission speed of microwaves, the time required for transmission and reflection is negligible.
| Model | KLD802 |
|---|---|
| Medium | Non-corrosive liquid, slightly corrosive liquid |
| Measuring Range | 0.1m~10/20/30/60/100m |
| Process Connection | Flange ≥ DN80 |
| Process Temperature | -40~110℃ |
| Process Pressure | -0.1~1.6 MPa |
| Antenna Size | 32mm lens antenna |
| Antenna Material | PTFE |
| Accuracy | ±1mm (range below 35m) ±5mm (range between 35m and 100m) |
| Protection Class | IP67 |
| Center Frequency | 80GHz |
| Launch Angle | 3° |
| Power Supply | Two-wire / DC24V Four-wire / DC12~24V Four-wire / AC220V |
| Casing | Aluminum/Plastic/Stainless Steel |
| Signal Output | Two-wire / 4...20mA/HART protocol Four-wire / 4...20mA/RS485 Modbus |
During installation, avoid positioning the instrument above material inlets and minimize proximity to signal-interfering objects such as stirring paddles.
Power Supply (4~20) mA/HART (2 wire): Power supply and output current signal share a two-core shielded cable. Refer to technical data for specific voltage range requirements.
(4~20) mA (4 wire/6 wire): Separate power supply required. Use four-core shielded cable for power and current signal (six-core required for simultaneous RS485 interface output).
RS485/Modbus: Separate power supply required. Use four-core shielded cable for power and digital signal (six-core required for simultaneous current signal output).
Observe local electrical installation regulations and personnel health and safety requirements. All electrical component operations must be performed by trained professionals. Verify instrument nameplate specifications meet your requirements and ensure power supply voltage matches nameplate specifications.
This instrument meets IP66/67 protection class requirements. Ensure cable sealing head waterproof integrity as shown:
IP67 Compliance Requirements:
Beam Angle: The beam angle represents the angle where radar wave energy density reaches half maximum value (3dB width). Microwave signals emitted beyond beam range may reflect off interfering objects.
| Lens Antenna Diameter | Φ32mm lens Antenna | Φ42mm lens Antenna | Φ76mm lens Antenna | Φ74.7mm lens Antenna with air purge |
|---|---|---|---|---|
| Beam Angle | 7° | 6° | 3° | 3° |
Larger antenna sizes with smaller beam angles (α) generate fewer interference echoes. For optimal measurement accuracy, avoid installing internal devices (limit switches, temperature sensors, bases, vacuum rings, heating coils, baffles, etc.) within the signal beam range.
|
|
KLD802 OEM 80GHz High Accuracy 1mm Radar Level Transmitter with IP67 Protection for Water Tanks Images |