Sign In | Join Free | My ecer.co.uk
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

7 Years

Home > Gas Detector Sensor >

KGD MQ 532 Infrared Gas Analyzer Explosion Proof Type For Accurate H2S Measurement NDIR In Hazardous Environments

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

KGD MQ 532 Infrared Gas Analyzer Explosion Proof Type For Accurate H2S Measurement NDIR In Hazardous Environments

Brand Name : KACISE

Model Number : KGD-MQ-532

Certification : CE

Place of Origin : CHINA

MOQ : 1PCS

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 1000 Piece/Pieces per Week negotiable

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Power Supply : AC220V, 50Hz

Measured Components : CO, CO2, CH4, C3H8, O2, H2S

Measurement Principle : NDIR, ECD

Measurement Range : CO/CO2/CH4/C3H8: (0 - 100%) ; O2: (0 - 25%) ; H2S: (0 - 9999) ppm

Linear Error : CO/CO2/CH4/C3H8: ±1%F.S.; O2/H2S: ±2%F.S.

Resolution : 0.01% (For low - range, the resolution of H2S can reach 1ppm)

Contact Now

KGD - MQ - 532 Infrared Gas Analyzer (Explosion - proof Type)

Product Introduction

The KGD - MQ - 532 Infrared Gas Analyzer (Explosion - proof Type) adopts non - dispersive infrared (NDIR) gas analysis technology with independent intellectual property rights and long - life electrochemical sensing technology. It can simultaneously measure the volume concentrations of gases such as CO, CO2, CH4, C3H8, O2, and H2S online. The instrument is equipped with pre - treatment, which can solve applications in harsh working conditions with water and dust on - site. Its explosion - proof design can meet the gas monitoring requirements in flammable and explosive places in multiple fields, ensuring the safety of industrial sites.

KGD MQ 532 Infrared Gas Analyzer Explosion Proof Type For Accurate H2S Measurement NDIR In Hazardous Environments

Product Features

  • Explosion - proof Design: The instrument adopts an explosion - proof design. The flame - proof enclosure separates the internal space of the equipment from the surrounding environment. It ensures that when an explosion occurs, the enclosure can withstand the explosion pressure without being damaged, and prevents the flame from passing through the flame - proof gap to ignite the external explosive environment.
  • High Measurement Accuracy: There is no cross - interference among multi - component measured gases, and the measurement accuracy is high. It has a self - diagnosis function and can check the sensor status online.
  • Stable Working Performance: The sensor adopts a dual - channel design, which is highly stable. All parts in contact with the sample gas are made of special heat - resistant and corrosion - resistant materials such as stainless steel and polytetrafluoroethylene.
  • High Degree of Automation: It is equipped with a professional pretreatment solution, featuring high automation and low maintenance. Real - time online monitoring can be achieved without manual attendance, greatly reducing the labor cost of enterprises.
  • Simple Data Management: Data can be transmitted to the superior centralized control system through multiple interfaces.

Technical Parameters

Parameter Details
Power Supply AC220V, 50Hz
Measured Components CO, CO2, CH4, C3H8, O2, H2S
Measurement Principle NDIR, ECD
Measurement Range CO/CO2/CH4/C3H8: (0 - 100%) ; O2: (0 - 25%) ; H2S: (0 - 9999) ppm
Linear Error CO/CO2/CH4/C3H8: ±1%F.S.; O2/H2S: ±2%F.S.
Resolution 0.01% (For low - range, the resolution of H2S can reach 1ppm)
Repeatability ≤2%
Response Time T90<15s (NDIR)
Optimal Flow Rate (0.7 - 1.2) L/min
Inlet Gas Pressure (2 - 50) kPa
Gas Requirements Dust - free, water - free, oil - free
Electrical Parameters Electrical parameters
Communication RS - 485/RS - 232; 4 - 20mA; Ethernet
Display LCD display
Explosion - proof Grade Certification Ex db IIC T6 Gb / Ex tb III C T80°C Db
Functional Configuration Built - in zero - adjustment air pump for automatic air zero - adjustment. Self - diagnosis function available, sensor status can be checked online.

Product Tags:

Explosion proof Infrared Gas Analyzer

      

NDIR Infrared Gas Analyzer

      

Accurate H2S Measurement Infrared Gas Analyzer

      
Quality KGD MQ 532 Infrared Gas Analyzer Explosion Proof Type For Accurate H2S Measurement NDIR In Hazardous Environments for sale

KGD MQ 532 Infrared Gas Analyzer Explosion Proof Type For Accurate H2S Measurement NDIR In Hazardous Environments Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)